Part Number Hot Search : 
GL8EG TPS2065D ARX4435N HVP35 G1962M AT1457 T491A47 AD602JN
Product Description
Full Text Search
 

To Download AMER90-36250AZ Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 1 of 11 north america only features: models single output model max output power (w) output voltage range (v) output current (a) input voltage (vac/hz) input voltage (vdc) mode of operation efficiency (%) 115 vac 230 vac 277 vac amer90-50180az 90 36-50 1.8 90-305/47-440 130-430 constant current 87 86 86 constant voltage exceeding the maximum output power will permanently damage the converter. ? the dimming feature is not supported when units are used in constant voltage mode only, aimtec suggests to order ?-f? no dimming ? option in the case. ? ? in constant current mode output current is maximum shown, in constant voltage mo de output voltage is the maximum shown. all models can be ordered with optional north american colour input wires (black (l), white (n), green (gnd)). add ??na? to part nu mber when ordering. note: aimtec limited warranty of 5 years is valid based on product operation at datas heet specifications at ambient temperatur e of 25c, humidity<75%, nominal input voltage (115/230/277vac) and at rated output load unless otherwise specified. see http://www.aimtec.com/terms-sale amer90-az?s ac/dc led drivers have electrical sa feguards designed within to protect it from conventional electrical abnormalities with the levels listed in t he safety table. applications for use within rural agricultur al, heavy industrial, and other areas or regions which are prone to ?dirty? electrical conditions which would subject any of the above models to exce ssive voltages surges or spikes, may damage or cause early life failure of product. in this case consideration should be made by the end user to ensure that adequate line or mains surge suppr ession is installed in front of aimtec device to ensure the longevity of the prod ucts. failure to identify excessive line surges violations prior to installation may damage sens itive equipment permanently. input specifications parameters conditions typical maximum units current (full load) 115 vac 1500 ma 230 vac 600 ma 277 vac 500 ma inrush current <2ms(cold start) 115 vac 40 a 230 vac 50 a 277 vac 60 a leakage current i/o 0.25 ma i/fg, o/fg 3.5 ma power factor 115 vac 0.98 230 vac 0.94 277 vac 0.90 external fuse recommended slow blow type 2.5 a start-up time 1000 ms ? ac-dc constant current or constant voltage led driver ? ? over current protection ? input range 90-305vac/47-440hz ? ? high efficiency up to 88% ? ? operating temperature -40 to 85c ? dimmable via resistive ? 5 years limited warranty ?
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 2 of 11 north america only output specifications parameters conditions typical maximum units current accuracy 3 % line regulation (ll-hl) 2 % load regulation 0-100% load 3 % ripple & noise * 150 mv p-p hold-up time 100 ms current adjustment range 100-10 % ripple and noise are measured at 20mhz bandwidth by using a 0.1 f (m/c) or (c/c) and 47f (e/c) parallel capacitor. note: from 0% to 10% dimming adjustment signal instability may be present. isolation specifications parameters conditions typical rated units tested voltage i/o 3sec 3750 vac i/fg 2000 vac o/fg 500 vac isolation resistance 500vdc >1000 m ? general specifications parameters conditions typical maximum units switching frequency 125 khz over current protection amer90-50180az 1.87 a AMER90-36250AZ 2.57 amer90-24375az 3.8 over voltage protection refer to constant current vs. constant voltage mode curve short circuit protection continuous short circuit restart auto recovery over temperature protection >105c operating temperature see derating table -40 to +85 o c maximum case temperature 100 o c storage temperature -40 to +95 o c temperature coefficient 0.02 % / o c cooling free air convection humidity non condensing 95 % rh case material aluminum potting epoxy (ip67 rated) wires ul1015 18awg input & 14awg output *20cm weight 900 g dimensions (l x w x h) 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm mtbf >400,000 hrs (mil-hdbk-217f at +25c) safety specifications parameters agency approvals culus, ce standards ul8750, ul60950-1, en55022, class b, en60529(ip68), en61347-1, en61347-2-13 information technology equipment en55022 class b harmonic current emissions iec/en 61000-3-2, class c voltage fluctuations and flicker iec/en 61000-3-3, (en60555-3) electrostatic discharge immunity iec 61000-4-2 level 3 rf, electromagnetic field immunity iec 61000-4-3 level 2 electrical fast transient / burst immunity iec 61000-4-4 level 2 surge immunity iec 61000-4-5 level 3 rf, conducted disturbance immunity iec 61000-4-6 level 2 power frequency magnetic field immunity iec 61000-4-8 level 1 voltage dips, short interruptions immunity iec 61000-4-11
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 3 of 11 north america only dimensions 59.00 (2.32) 181.00 (7.13) 47.00 (1.85) 200.00 (8.00) 200.00 (8.00) 2.30 (0.09) end view top view side view input/output wires are 18 awg 20cm 41.00 (1.73) 8.00 (0.32) 11.00 (0.43) 4.00 (0.16) 23.00 (0.91) measurements in millimeters (inch) case tolerance: 0.5 (0.02) 27.00 (1.06) wire connection: analog (resistive) dimming application circuit wire connection brown ac l blue ac n green ground red +v output black -v output blue (dimming) + vs dimming white (dimming) -vs dimming model number maximum pot value (k ? ) amer90-50180az 11.70 AMER90-36250AZ 16.95 amer90-24375az 28.09
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 4 of 11 north america only analog (0-10v) dimming a pplication circuit pwm (1khz) dimming application circuit temperature graph
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 5 of 11 north america only efficiency vs. input voltage and output current (cc load) amepr90-50180az AMER90-36250AZ
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 6 of 11 north america only efficiency vs. input voltage and output current (cc load) (continued) amer90-24375az pfc value vs. output load current (cc load) amepr90-50180az
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 7 of 11 north america only pfc value vs. output load current (cc load) (continued) AMER90-36250AZ amer90-24375az
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 8 of 11 north america only pfc value vs. output power AMER90-36250AZ amer90-24375az
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 9 of 11 north america only constant current mode vs. constant voltage mode amepr90-50180az AMER90-36250AZ
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 10 of 11 north america only constant current mode vs. constant voltage mode (continued) amer90-24375az output current vs. radj amepr90-50180az
series amer90-az up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.af 11 of 11 north america only output current vs. radj (continued) AMER90-36250AZ amer90-24375az note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency cert ifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an am bient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary an d may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sys tems or other such applications which necessitate specific safety and regulatory standards ot her the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s st andard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AMER90-36250AZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X